Greenheck will be closed Thursday, July 4th in observance of the July 4th holiday. Please note that shipments on July 5th may incur shipment delays. Full order shipments will resume on Monday, July 8th.
Shipping Type | Order By |
---|---|
Standard Ground Small Parcel FREE - On orders over $25 View Transit Map |
7:00 PM CST |
Next Day Air (Calculated at checkout) |
3:00 PM CST |
Standard Ground Freight FREE - On orders over $25 |
1:00 PM CST |
Shipping Type | Order By |
---|---|
Standard Ground Small Parcel FREE - On orders over $25 View Transit Map |
7:00 PM CST |
Next Day Air (Calculated at checkout) |
3:00 PM CST |
Standard Ground Freight FREE - On orders over $25 |
1:00 PM CST |
Find a fan that's compatible with your performance needs by entering the following:
To calculate the CFM required to adequately ventilate an area, we divide the room volume by the appropriate “Minutes per Change” value.
Airflow (CFM) per Fan
Starred items represent required fields.
Non-Ducted 0.05" to 0.20"
Ducted 0.20" to 0.40" per 100 feet of duct (assuming duct air velocity falls within 1,000 to 1,800 feet per minute)
Fittings 0.08" per fitting (elbow, register, grill, damper, louver, duct turn, etc.)
Kitchen Hood Exhaust 0.625" to 1.50"
Important: Static pressure requirements are significantly affected by the amount of make-up air supplied to an area. Insufficient make-up air will increase static pressure and reduce the amount of air that will be exhausted. Remember, for each cubic foot of air exhausted, one cubic foot of air must be supplied.
To calculate the CFM required to adequately ventilate an area, we divide the room volume by the appropriate “Minutes per Change” value.
Airflow (CFM) per Fan
Starred items represent required fields.
Non-Ducted 0.05" to 0.20"
Ducted 0.20" to 0.40" per 100 feet of duct (assuming duct air velocity falls within 1,000 to 1,800 feet per minute)
Fittings 0.08" per fitting (elbow, register, grill, damper, louver, duct turn, etc.)
Kitchen Hood Exhaust 0.625" to 1.50"
Important: Static pressure requirements are significantly affected by the amount of make-up air supplied to an area. Insufficient make-up air will increase static pressure and reduce the amount of air that will be exhausted. Remember, for each cubic foot of air exhausted, one cubic foot of air must be supplied.
SKU | DRIVE TYPE | HP | VOLTAGE | MOTOR PHASE | CFM RANGE | FRPM RANGE | PRICE | LEAD TIME | |||
---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Model:
SE1
Model / Size:
SE1-14
|
Direct Drive | 1/3 | 115 | 1 | 1220-2734 | 1400-1750 | $655.27 |
In stock
1 on Hand
|
Add to Compare List |
|
![]() |
Model:
AS
Model / Size:
AS-14
|
Direct Drive | 1/2 | 115/230 | 1 | 1380-2586 | 1400-1750 | $1,224.17 |
In stock
2 on Hand
|
Add to Compare List |
|
![]() |
Model:
GPI
Model / Size:
GPI-34
|
- | - | - | - | - | - | $325.62 |
In stock
6 on Hand
|
Add to Compare List |
|
![]() |
Model:
AS
Model / Size:
AS-16
|
Direct Drive | 3/4 | 115/230 | 1 | 1200-2920 | 1400-1750 | $1,335.28 |
In stock
3 on Hand
|
Add to Compare List |
|
![]() |
Model:
SE1
Model / Size:
SE1-18
|
Direct Drive | 3/4 | 115/230 | 1 | 2024-4886 | 1400-1750 | $785.95 |
In stock
2 on Hand
|
Add to Compare List |
|
![]() |
Model:
GPI
Model / Size:
GPI-40
|
- | - | - | - | - | - | $389.90 |
In stock
1 on Hand
|
Add to Compare List |
|
![]() |
Model:
BSQ
Model / Size:
BSQ-70
|
Belt Drive | 1/4 | 115 | 1 | 142-429 | 1505-1972 | $1,588.23 |
In stock
2 on Hand
|
Add to Compare List |
|
![]() |
Model:
BSQ
Model / Size:
BSQ-80
|
Belt Drive | 1/4 | 115 | 1 | 242-756 | 1385-1833 | $1,618.00 |
In stock
2 on Hand
|
Add to Compare List |
|
![]() |
Model:
CSP-A
Model / Size:
CSP-A110
|
Direct Drive | - | 115 | 1 | 77-124 | 760-950 | $303.10 |
In stock
137 on Hand
|
Add to Compare List |
|
![]() |
Model:
CSP-A
Model / Size:
CSP-A125
|
Direct Drive | - | 115 | 1 | 91-138 | 880-1100 | $303.10 |
In stock
267 on Hand
|
Add to Compare List |
|
![]() |
Model:
SP-A
Model / Size:
SP-A1050
|
Direct Drive | - | 115 | 1 | 662-1125 | 876-1095 | $941.29 |
In stock
17 on Hand
|
Add to Compare List |
|
![]() |
Model:
CSP-A
Model / Size:
CSP-A200
|
Direct Drive | - | 115 | 1 | 70-254 | 720-900 | $360.34 |
In stock
309 on Hand
|
Add to Compare List |
|
![]() |
Model:
SP-A
Model / Size:
SP-A110
|
Direct Drive | - | 115 | 1 | 98-130 | 760-950 | $220.37 |
In stock
620 on Hand
|
Add to Compare List |
|
![]() |
Model:
CSP-A
Model / Size:
CSP-A250
|
Direct Drive | - | 115 | 1 | 82-266 | 800-1000 | $360.34 |
In stock
131 on Hand
|
Add to Compare List |
|
![]() |
Model:
CSP-A
Model / Size:
CSP-A390
|
Direct Drive | - | 115 | 1 | 281-412 | 1080-1350 | $421.32 |
In stock
328 on Hand
|
Add to Compare List |
Model SE1, direct drive, sidewall propeller exhaust fans provide general ventilation in commercial and industrial applications. Units feature corrosion resistant aluminum propellers and are ideal for quietly exhausting air in schools, storage facilities, and manufacturing and assembly areas.
Model AS, direct drive axial supply fan is designed for economy and reliability in low pressure/low volume applications. Typical applications include general clean air ventilation.
GPI roof curbs are designed for flat, insulated or non-insulated roof decks. Constructed of 18 gauge galvanized steel and fully formed on three sides with a single, fully welded seam.
Model AS, direct drive axial supply fan is designed for economy and reliability in low pressure/low volume applications. Typical applications include general clean air ventilation.
Model SE1, direct drive, sidewall propeller exhaust fans provide general ventilation in commercial and industrial applications. Units feature corrosion resistant aluminum propellers and are ideal for quietly exhausting air in schools, storage facilities, and manufacturing and assembly areas.
GPI roof curbs are designed for flat, insulated or non-insulated roof decks. Constructed of 18 gauge galvanized steel and fully formed on three sides with a single, fully welded seam.
Model BSQ centrifugal inline fan features a unique combination of installation flexibility, rugged construction, ease of service, high efficiency and low sound levels. These compact fans are the ideal selection for indoor clean air applications including intake, exhaust, return or make-up air.
Model BSQ centrifugal inline fan features a unique combination of installation flexibility, rugged construction, ease of service, high efficiency and low sound levels. These compact fans are the ideal selection for indoor clean air applications including intake, exhaust, return or make-up air.
Model CSP inline fans are high performance fans designed for exhaust, supply or return air applications where low sound level are required. Units feature an insulated, galvanized steel housing with a forward-curved wheel.
Model CSP inline fans are high performance fans designed for exhaust, supply or return air applications where low sound level are required. Units feature an insulated, galvanized steel housing with a forward-curved wheel.
Model SP-A direct drive, ceiling mounted fan is designed to provide the lowest sounds levels for bathroom exhaust. Units feature an insulated housing and are ideal for residential, multi-family or hotel applications.
Model CSP inline fans are high performance fans designed for exhaust, supply or return air applications where low sound level are required. Units feature an insulated, galvanized steel housing with a forward-curved wheel.
Model CSP inline fans are high performance fans designed for exhaust, supply or return air applications where low sound level are required. Units feature an insulated, galvanized steel housing with a forward-curved wheel.
Model CSP inline fans are high performance fans designed for exhaust, supply or return air applications where low sound level are required. Units feature an insulated, galvanized steel housing with a forward-curved wheel.
Our performance filter tool can help you choose the right product based on your performance requirements.